IIS: 27¶2 - .I964 Indian Standard ( Reaffirmed 2000 ) CODE OF PRACTICE FOR DESIGN AND CONSTRUCTION OF STONE SLAB OVER JOIST FLOOR ( Third Reprint .K! N E 1990 ) UDC693.154:694.5:69.025.26 @ Copyright 1964 BUREAU MANAK OF INDIAN 9BAHADUR STANDARDS SHAH ZAFAR MARG BHAVAN, NEW DELHI llCXlU2 a.srm-la64 Indhz Standard CODE OF PRACTICE FOR. DESIGN AND CONSTRUCTIC?N OF STONE SLAB-OVER JOIST FLOOR Building Construction Practicis Central Sectional Committee, BDC 13 Chairman SIIRI N. G. QIMAS Membrrs Strnr J. P. J BILIYORIA DBP::TY DIBECTOR ( AUCI~ITECTuRE ) PROI'. D~wmsa MOHAN DIRECTOR SHRI C. M. GOVEAS SIIRI s. K. JOoLI.:xAX SHRI s. B. Josu1 SHRI H. N. Josur ( Al/ernole) SARI \`. S. KAIAT SHRI K;eWAL );RlIHAS Re@wding Public Works Department ~~e~m\nstitute. of Architects, Bombay ,. Dcngns and Standards Organisation (-Minatry of Railways ) Ccnt;rar~cilding Rcscarch Institute ( CSIR ), Engineering Research Department, Andhra Pradesh Atomic Energy Commission Central Public Works Department S.B. Joshi & Co. Ltd., Bombay Government of The Hindustan Construction Co. Ltd., Bombay Public Works Department, Government of Punjab; and Soil Construction Subcommittcc~ BDC 13 : 8, IS1 Forei;dRcsT;hbytute and Colleges, Debra Dun; SHRI N. J. MASANI Subcommlttec, Engmeering BDC i 3 : 4, IS1 The Concrete Association of India, Bombay: and Sillli K. li. NAMlUAR Concrete Construction Subcommittee, BDC 13 :9, IS1 Sum N. H. hfonrr.~( Al&m& ) The Concrete Associatrba of India, Bombay National Buildings Organisation ( Ministry of Sum C. B. PATEL Works & Housing ) ; and Expansion Joints Subcommittee. BDC 13 : 14. 181 SHIUM. A. HAFERZ( Alfrrnatc ) National Buildings O&&ion ( Ministry of Works & Housing ) Hindustan Housing Factory, New .DeIhi SIIRI D. J. PATEL Enrrincer-in-Chief's Branch, Army Headquarters SHRI M. L. RAE~.JA Saar R. D. IUATIIITR ( Alternate) Institution of Surveyors, New Delhi Bmo K. B. RAI Institution of Engineers ( India), Calcutta Stw RAMBILAS Covering, Veneering and Glazing Subcommittee, SARI N. S. L. RAO BDC 13: 10, IS1 Builders' Association of India, Bombay REFRESENTATIVE Masonry Construction Subcommittee, BDC 13 : 7, ISI REPRESENTATIVE ( Continued on page 2 ) BUREAU MANAK OF BHAVAN, INDfiAN STANDARDS %AFr\K MARC. !I BAIIADUR SllAH NEW DI:.I.IlI I IOOO? National Building Construction Cwpration Ltd., New Delhi Directorate General of Health Services ( Mioistry of Health ) Public Works Dc rtmcnt, Government of Mndrax mad Brick an c? Tale Fluoi and Roof Constructicil Subcommittee, BDC I3 : 1I, IS1 Dircctw, IS1 ( I&-ofiio ALl?rlcr i Assistant Director ( Bldg ), IS1 Brick and Tiie Floor and Roof Construction BDC 13: 11 Subcomnittee, Public Works Department; Ciwcrnment of bfa*iraa Southerr! Railway, Madras SmuC. R. NABAYAXA RAO SHIU F.B. PITEAVADIAN Institute ( CSIR ), Cerrlral Building R~rarch Roorkee In personal capacity ( Lu~-I~[TII~/~c, AMrus ) Prynne, Abbott and Davii, Madras Public Works Department, Covert:mcnt of Kerala The Concrete Association of India, B.>mhay Public Works Department, G~~vernmcnt of .Ilysorr: Publi;r~~;s Public Works Dcpartmcnt, Ikpartmcn!, Government Government of Andhra of Madras SWIWEWE OF CVORR~(MADRAS CENTRALCUWLE ) Central Public \Vorks Urpartment ISt2792-1964 Indian Standard CODE OF PRACTICE FOR DESIGN AND CONSTRUCTION OF STONE SLAB OVER JOIST FLOOR O.,FOREWORD 0.1 This Indian Standard was adopted by the Indian Standards Institution on 30 *July 1964, after the draft finalized by the. Building Construction Practices Sectional Committee had been approved by the Building Division Council. 0.2 Slabs of natural stone such as granite, limestone, sandstone, etc, are largely used for floor and roof construction in parts of Andhra Pradesh, Mysore, Maharashtra, Rajasthan, Uttar Pradesh, ctc, where such stones are available jn plenty. This standard is intended as a guide for the design and construction of this type of work. 0.3 The Sectional Committee responsible for the preparation of this standard has taken into consideration the views of producers, consumers and technologists and has related the standard to the manufacturing and trade practices followed in the, country in this field. Due weightage has also been given to the need for international co-ordination among standards prevailing in different countries of the world. 0.4 For the purpose of deciding whether a particular requirement of this standard is complied with, the final value, observed or calculated, expressing the result of a test or analysis shall be rounded off in accordance with IS : 2-1960*. The number of significant places retained in the rounded off value should be the same as that of the specified value in this standard. 1. SCOPE 1.1 This standard covers the. design and construction of structural roofs where stone slabs are supported over closely spaced joists and with a layer of lime concrete or cement concrete and the requited roof finish. The standard also specifies the material used construction, *Rules for rounding oiT numerical wducs ( r~mkul ). floors or covered floor or for this 3 ISr2792-1961 2. TERMINOLGGY 2.1 For descriptions IS : 180%1961*. 3. NECESSARY INFORMATION of various types of stones reference may he m,ade to ' 3.1 Par efficient design,and with regard to the following construction is necessary: of the \\-ork, dctailcd information a) Dimensions of the area to be covered; ' b) Type of supporting structures and restrictions, if an)-; c) *Level to which the walls or supports should be brought to receive the floor; d) Treatment at junctions with adjacent floors, wails, etc; and e) Provision to be made in the wall or supports themselves for floor slopes and other requirements and for lixing services, ceiling, etc. 3.2 All information concerned instructions as in 3.1 should be made available to those who are with the design and construction. Necessary drawings and for preparatory work shall be given. 3.3 Arrangements shall also be made for proper exchange of information between those engaged in laying the floor and ail others whose work will afi'ect or will be affected. 4. DESIGN CONSIDERATIONS stone slab and joist floor will cousist of the follo\+g 4.1 General -The components. Typical derails of Ihc floor arc sho;vn in I'& 1: a) Joists spaced at 30 to 80 cm apart to support the floor slab. b) Stone slabs of specified dimensions closely placed over the supporting joists so as to span between them. The slabs may `either be placed on the top of the joist or in the case ofjoist with .a bottom flange, such as a rolled steel joist, may be placed over the bottom flange. Unless special precautions for waterproofing of roof are taken, rusting of s!abs on the botrom Aalge would not generally be suitable for roof; for floor ivork, this construction may be permitted as one of the alternatives at the option of the designer depending upon the requirements for appearance and also the size of the joist that is chosen. c) A layer of lime concrete.or cement concrete over the stone slabs so as to obtain insulation and waterproofing. -- . . . _ _ -. -_--._- *Glas.sary of terms `,Since rcviacd j . relating to occurrcncc, quarrying and dressing of building stones. 4 IS : 2792 - 1964 rFLOOR OR ROOF FIN& LIME OR CEMENT CONCRETE BA!x -It-- 25 mm MIN WOODEN BEAM TYPICAL SECTION OF RCC JOIST NOTE Precast RCC STOXE TYPICAL SECTION OF STEEL JOIST or steel joists may bi USd OVEB JOIST FI,OOR FXQ. 1 SLAB 4.2 Strength and Stability 4.2.1 The permissiblb stresses in transverse bending for the various types of slonc slabs shall not exceed 1/lO of the ultimate transverse strength tlctermined in accordance with IS :1121-1957*. SOT]: - The following valu,cs for pcrmissiblc granite, sandstone and limestone: Granite Sandstone Limestone strcsscs may bc used in calculations 15 kg/cm2 8 kgjcms 8 kg/cm* for 4.2.1.1 In the"absence of specific data regarding the particular of stone used, the unit weight for stone to be used in calculations generally be 2 700 kg/m3. .`, type shall 4.2.2 The bearing width of joists carrying the slab shall not in any case For bearing he less than 25 mm nor more than half the width of the joist. over the wall, the stone slabs shall be bedded over a layer of mortar of thickness not, less than 12 nim. 4.2.3 The joists shall. be designed as beams s,upporting the floor laid over them. In designing the joists the dead load of stone floor, concrete --_ *iMethods of determination of compressive transverse and shear streng& of natural building stones. 5 and finishinp and'the IS : 875-l!&* i and Standards as below: live loads the design shall shall be taken into consideration ($88 conform to the relevant Indian IS : 4!%-l964t and IS : 1343~1960$ IS : 800_1962§ IS : 8834961~1 Precast reinforced cement concrete beams S tee1 beams Timber beams 4.2.4 The slope provided for roof drainage in stone slab fl00i ConstNCtion shal! not be 1~3s than 1 in 48, and this slope may be provided either in the lime-brick-jells concrete layer or in the joists. 5. MATERIALS 5.1 Cement .-. shall conform to the requirements of ordinary portland c'crnen! as laid down in IS : 269-1958y or blast furhace slag cement conffIIXliIJ~ i0 IS : 45.5136!2*+. 5.2 I;ime -- shall conform shali conform to IS : 712-1956tt. to IS : 1344-1959$$. 5.3 Sirkhi - 5.4 Aggrtgatt - shall generally conform to IS : 383-1963$$. Where brick aagregate is used it shall confurm.to Appendix B of IS : 2119-1962$1. 5.5 Water - shall be free from earthy, vegetable or oiganic matter and from salts or other substances likely to interfere with the setting of mortar cJr otlhcr\vIse prove harmful to the work. 5.6 Rolled &eel Stctions- shall conform to IS : 226-1962!1i. 5.7 Structural Timber - shall conform to IS : 883-1961/j. -_-__.__-*Code OFpractice for structural safety of buildings; loading standards. t&tie of practicefor plain and reinforced concrete ( second revision ). fCode oi prac& practice for prestressed concrete. steel 5Code,6f for .UC of structural in general building construction. timber in building ( material, grading and !@I& of practice for-use of structural drrign j ( rrrGcd ). ( Third revision issued ). TSpcil!ration for ordinary, rapid-harden&g and low heat portland cement ( revised). I T&d ,revisGn issued ). l *Pior!land blast furnace slag cement ( rcviseJ L ( Since revised ). t?Speciiitation for buiidin + limes. ( Second rev&ion ~#ued ). "' $:%pecification kx surkh or use i? m+ar and conc&te. ( Since revised ). &peciiication for coarse and fine aggregates from natural +trccs for &cretc. [`SewtAd revision issued ). ;/i;codc of practice for construction of brick-cum-concrete composite ( Madras terrace j floor `or root:. $ySpeclhcation for structural s&cl, standard quality ( revised ) .:( Fc&th r&&n imu&' ; 6 IS : 2792 - 1964 5.8 Stone Slab -may natural building stones: a) Granite, b) Sandstone c) Limestone, d) Slate. 5.8.1 Stone slabs as obtained from the quarry shall. be hard, durable and tough. They shall be $rce from decay, sand holes, flaws, cracks and other defects. They shall be quarried in such a way as to be suitable for the floor slabs. 5.8.2 The thickness of a slab at every point shall not be less than what specified for use in accordance with structural calculations, subject tn a tiinimum of 3 cm. The tolerance on stone dimensions shall be the same as given in IS : 1127-1957*. is be generally of one of the following types of including and quartz&, 5.8.3 The slabs may be flat chisel dressed to a smooth or rough surface according to the requirements of finishes at top and bottom of the floor. 5.8.4 The slabs shall toughness al?d durability seasoning and dressing. not absorb of a newly more than 5 percent of water. Tlie quarried stone may be improved Sy When tested for transverse strength in accordance with the procedure laid down in IS: 1121-19577, the stone shall have a strenyh of not less than 55 kg/cm'. 5.9 Lime flooring ,in Concrete -The sha!l be prepared IS : 2.541f. lime concrete for use over the stone ~!a\? in accordance with the requirements ?;pecitkt! l%r use over the stone with t!le requiwments 5.10 Cement Cbncrete - `The cement concrete slab flooring shall be prepared in accordance specified in IS : 456- 1964s. `6. PROGRAMMING THE WORK in 6.1 and 6.2 are necessary and shail with the stone slab floor construcGon br for 6.0 The facilities mentioned provided to the person entrusted carrying out his work satisfact;orily. elements lih~. 6.1 Completion of Precediag Work - All supporting sufficiently early a~rj walls, pillars, rndn beams, etc, shall be completed ~_______ . *Specification fur dimensionsand workmanslCpof natural buhding stone>. < Sil,cL for, determination of compressive, transverse and sheer strcrlgth ,,I' nit !t:!`:1: buildingstones. $Code of pfactice for use of lime concrete in buildings ( w&r /+mhn ;. : +,;,>c: puhiished and revised in 1974 j. %&de of practice for plain and reinforced concrctc ( second rcri.d 1. revised ). tMetnods cured well befbre the flooring work is taken supporting elements shall be finished level. up. The top surface of of the 6.2 -king of Levels - The exact levels of the bearing surface joist shall be previously checked and marked. 7. PREPARATORY WORK 7.1 Stop, Transport and HIPdltrg of Materials -Necessary precautions shall be observed in storage, transport and handling of stone slabs so that they are not broken or seriously damaged before laying on the floor. Other construction materials such as cement, lime, sand, etc, shall be stored and handled in accordance with the provisions given in the relevant Indian Standard specifications for the materials. the edges shall be chiseled 7.2 Preparation of Stone Slabs -All so,that the mortar joints will be of even thickness. 7.3 Treatment of Joists Before Erecdonpainted with one coat of primer before fixing. square All steel work shall be In the case of timber joists the portion that is set in masonry, shall be given protective finish with two coats of hot boiled tar conforming. to Before fixing joists one coat of primer paint shall also be IS : 212-1961". applied to the exposed portion of the joists. 8. FIXING OF JOISTS so as to 8.1 The joists shall be fixed in position at the designed spacing span between, the supporting elements, such as tealis, beams, etc. 8.2 The space between the ends of adjacent joists shall be filled with the same masonry or concrete as the bne on which they rest, so that the filled in masonry or concrete and the joists present an even and level surface at top for bearing of the floor. 9. LAYING OF STONE SLABS 9.1 The stone slabs shall be placed over the beams. The bearing of the slabs over the joists shall be in accordance with 4.2. The slabs shall be set in rows close to each other and the joints .grouted with cement-sand mortar The mortar shall be of stiff consistency and shall be pressed of mix 1:3. into the joints. It may be desirable to treat the mortar with crude oil, the ratio of crude oil being 5 percent that of the weight of the cement. On the underside the joints may be pointed or other types of ceiling finish applied as specified. `Specification for crude coal tar for general use ( mid). 8 IS : 2792 - 1964 10. LAYING OF CONCRETE LAYER OVER THE STONi% SLAB .lO.l Lime Concrete - After the stone slabs have been laid and grouted, a layer of lime concrete of mix 1 : 1 : 2 shall be laid so as to ensure adequate However, for situations waterproofing, such as in the case. of roofs. where exposure to weather is not much, or where additional waterproofina finish is provided, the mix may `be of 1 : 14 : 3. The mix shall be so laid The lime as to form a level surface and have a uniform thickness. concrete shall, after laying, be well beaten with wooden hand beaters SG The consolidated ~llickness that it is consolidated evenly to a level surface. shall be not less than 7.5 cm. 10.1.1 The beating shall continue until the concrete harden!. an:1 the beater makes no impression on the cmcre:r and readily rebound5 from the surface when struck on it. Care shall be taken not to beat the concrete so hard as to crack the slabs: particularly where slabs of low strength are used. The whole surface shall be subsequently wetted by sprinkling lime water. If the surface during the process of hearing becomes so uneven that water collects in pools, the surface shall be picked up and fresh The concrete ihall be concrete added and reconsolidated as necessary. cured by sprinkling water and allowed to harden for a period of not less than six days before laying the floor or roof finish. 10.2 Cement Concrete base for a floor finish 11. FINISHING - This shall be laid in the same ( see for example, 1S : 2 11 -I- 1Yt;2* j. manner as thr with either cement plaster of mix 1 : 3, 20 mm thick or other types of floor or roof finish as required in accordance with the relevant Indian Standards ( set Note ). NOTE- Indian enlisted below: Terrazzo flooring Standards covering suitable IS finishes over atotic slab floor are 11.1 The stone floor may be finished Finish with cemefit tiles Mud PHUSKA-rod%& Mastic asphalt flooring : 144!3- 1459t IS: 2114-196P IS:2115-19&q IS : 1196.1958f( *Code of practice for laying in-situ terrazzo floor finish. tCodc of practice for laying and finishing of cement concrete flooring tiles. ( Since revised ) . $&de of practice for Rat roof finish : mud PHUSICA. ( Since revised ). $Code of practice for laying mastic asphalt Rooring. (since revised ). 9 BUREAU Headquarters: OF INDIAN STANDARDS Manak Bhavan, 9 Bahadur Shah Zafar Marg, NEW DELHI 110002 Telephones: 331 01 31, 331 13 75 Regional Offices: Central : Manak Bhavan. 9 Bahadul Shah Zafar Marg, NEW DELHI 110002 *Eastern : l/l 4 C. I. T. Scheme VII M, V. I, P. Road, Maniktola, CALCUTTA 700054 Northern : SC0 445-446, Sector 35-C, CHANDIGARH 160036 Telegrams: Manaksansthe ( Common to all Offices ) Telephone 331 01 31 331 1375 I 36 24 99 21843 I 3 16 41 41 24 42 Southern : C. I. T. Campus, MADRAS 600113 41 25 19 ( 41 2916 tWestern : Manakalaya, E9 MIDC, Marol, Andheri ( East ), 6 32 92 95 BOMBAY 400093 Branch Offices: `Pushpak'. Nurmohamed Shaikh Marg, Khanpur, 2 63 b8 AHMADABAD 380001 I 2 63 49 SPeenya industrial Area 1st Stage, Bangalore Tumkur Road 38 49 55 BANGALORE 560058 38 49 56 I Gan'gotri Complex, 5th Floor, Bhadbhada Road, T. T. Nagar, 667 16 BHOPAL 462003 Plot No. 82183. Lewis Road. BHUBANESHWAR 751002 5 36 2: 53j5. Ward No. 29, R.G. Barua Road, 5th Byetane, 3 31 77 GUWAHATI 781003 5-8-56C L. ,N. Gupta Marg ( Nampally Station Road ), 23 1083 HYDERABAD 500001 634 71 R14 Yudhister Marg. C Scheme, JAIPUR 302005 f 6 98 32 21 68 76 117/4 18 B Sarvocidva Nagar, KANPUR 2a8005 ( 21 82 92 Patliputra lndusttlal Estate, PATNA 800013 6 23 05 T.C. No. 14/l 421. University P.O.. Palayam 16; 21 04 TRIVANDRUM 695035 1621 17 fnspection Offices ( With Sale Point 1: Pushpanjali. First Floor, 205-A West High Court Road, 2 51 71 Shankar Nagar Square. NAGPUR 440010 Institution of Engineers ( India ) Building, 1332 Shivaji Nagar, 5 24 35 PUNE 411005 _.___-. ._..__.. .-.--. ---*Sales Office In Calcutta is at 5 Chowringhee Appro